Edukasi Pemeriksaan MSCT Stonografi dan Pemanfaatan Teh Oolong sebagai Alternatif Media Kontras Negatif bagi Radiografer dan Mahasiswa Radiologi
DOI:
https://doi.org/10.38215/wsrsqj38Keywords:
MSCT, oolong tea, radiographers, stonographyAbstract
This Community Service (PKM) activity aims to provide education for radiographers and final-year radiology students regarding Multi-Slice Computed Tomography (MSCT) Stonography and the utilization of oolong tea as an alternative negative contrast medium to support ureter visualization. The activity is conducted online via Zoom on March 11, 2024, involving 30 participants. The method consists of interactive presentations, visual demonstrations, discussions, and question-and-answer sessions. The educational materials cover patient preparation and education, positioning, examination protocols, scanning and tracking procedures, Curved Planar Reconstruction (CPR), and the use of oolong tea in MSCT Stonography examinations. Evaluation is conducted descriptively based on participant involvement during discussions and question-and-answer sessions, without the use of pre-test and post-test assessments. As supporting data, 30 MSCT Stonography cases are analyzed to examine the association between oolong tea use and ureter visualization. The analysis shows a significant association in the visualization of the distal ureter (p = 0.000) and medial ureter (p = 0.001). Participants actively engaged in the activity, particularly during the discussion and question-and-answer sessions. This activity provided an educational and practical approach to strengthening understanding of MSCT Stonography examination techniques and introducing oolong tea as an alternative negative contrast medium to support ureter visualization.
Downloads
References
Agustin, A. V. K. (2025). Perbedaan Variasi Suhu Dan Lama Penyeduhan Teh Oolong (Camellia sinensis (L.) Kuntze) Terhadap Kadar Senyawa Flavonoid Total.
Azam, G., Salman Khalid, Raza Ullah, Syeda Tahreem Zahra, Shah Zeb, & Muhammad Usama. (2025). Role Of Contrast And Non-Contrast Computed Tomography In Evaluation Of Obstructive Kidneys. Insights-Journal of Health and Rehabilitation, 3(6), 95–103. https://doi.org/10.71000/ZMP6W750
Bushong, S. C., & Shields, E. (2025). Bushong's radiologic science for technologists: Physics, biology, and protection (13th ed.).
Mosby.. da Costa, A., Astina, K. Y., & Darmita, I. M. P. (2025). Variasi Slice thickness dan Rekonstruksi Increment Terhadap Informasi Citra Anatomi Pemeriksaan MSCT Stonografi Pada Kasus Nephrolithiasis. Jurnal Surya Medika, 11(3), 5–12. https://doi.org/10.33084/jsm.v11i3.8249
Den Otter, T. D., & Schubert, J. (2023). Hounsfield Unit. Radiopaedia.Org. https://doi.org/10.53347/rid-38181
Jain, S., & Chen, F. (2019). Developmental Pathology of Congenital Kidney And Urinary Tract Anomalies. Clinical Kidney Journal, 12(3), 382–399. https://doi.org/10.1093/CKJ/SFY112
Lampinano, J. P., & Kendrick, L. E. (2018). Textbook of Positioning and Related Anatomy (9thed.). Elsevier, Inc.
Munawar, A., Khan, M., Hasnain, M. A. Z., Hussain, R. N., Younas, S., Bahar, K., & Ullah, M. M. Z. (2024). Computed Tomography Findings In The Evaluation of Urolithiasis. Journal of Health and Rehabilitation Research, 4(2), 164–170. https://doi.org/10.61919/jhrr.v4i2.767
O'Connor, O. J., & Maher, M. M. (2010). CT Urography. American Journal of Roentgenology,195(5), W320–W324. https://doi.org/10.2214/AJR.10.4198
Rahmat, L. J. (2022). Pengaruh penggunaan window display terhadap gambaran ureter dengan kasus urolithiasis pada pemeriksaan ct stonogram di rsup dr.hasan sadikin bandung. Jurnal Teras Kesehatan, 5(1), 1–10. https://doi.org/10.38215/jtkes.v5i1.94
Rahmat, L. J., Damayanti, O., Ardiana, A., & Nilasari, V. (2024). Manfaat teh oolong terhadap gambaran ureter pada pemeriksaan MSCT stonografi pada kasus urolithiasis di Rumah Sakit Umum Pusat Dr. Hasan Sadikin Bandung. Jurnal Cahaya Mandalika, 3(3), 2113–2124.
Louis, R. (2011). Computed Tomography for Technologists A Comprehensive Text. Lippincott Williams & Wilkins. https://www.scirp.org/reference/referencespapers?referenceid=2010884
Seeram, E. (2016). COMPUTED TOMOGRAPHY: Physical Principles, Clinical Applications, and Quality Control (4th ed.). Elsevier. http://evolve.elsevier.com/Seeram/YOU’VEJUSTPURCHASED
Susilowati, A., & Nur’aini, N. S. (2022). Efek Diuretik Seduhan Daun Teh Hijau (Camellia sinensis L.) Pada Mencit Jantan Galur Swiss. Jurnal Ilmiah Manuntung: Sains Farmasi Dan Kesehatan, 8(1), 120–125. https://doi.org/10.51352/jim.v8i1.511
Türk, C., Petřík, A., Sarica, K., Seitz, C., Skolarikos, A., Straub, M., & Knoll, T. (2016). EAU Guidelines on Diagnosis and Conservative Management of Urolithiasis. European Urology, 69(3), 468–474. https://doi.org/10.1016/j.eururo.2015.07.040.
Wang, S., Zeng, T., Zhao, S., Zhu, Y., Feng, C., Zhan, J., Li, S., Ho, C.-T., & Gosslau, A. (2022). Multifunctional Health-Promoting Effects of Oolong Tea and Its Products. Food Science and Human Wellness, 11(3), 512–523. https://doi.org/10.1016/j.fshw.2021.12.009
Downloads
Published
Issue
Section
License
Copyright (c) 2026 JURNAL ABDI GUNA

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.