Evaluasi Dosis CT Scan Kepala Trauma Terhadap Nilai I-DRL
DOI:
https://doi.org/10.38215/4my9ny49Keywords:
CTDIvol, CT-Scan, Dose Length Product, TraumaAbstract
This study aims to analyze the correlation between age and Body Mass Index (BMI) with the Computed Tomography Dose Index Volume (CTDIvol) and Dose Length Product (DLP) in non-contrast head CT scans performed on trauma patients. This observational analytic study employed a retrospective approach involving 30 adult patient samples. The results showed an average CTDIvol value of 65.18 mGy, exceeding the national Diagnostic Reference Level (DRL) established by BAPETEN (60 mGy). Nevertheless, this value is consistent with the use of the standardized “Brain Trauma” protocol and a uniform tube voltage of 120 kV. The CTDIvol ranged from 42.4 mGy to 103 mGy, indicating data homogeneity, with an average DLP of 1779.97 mGy·cm, significantly surpassing the national DRL (1275 mGy·cm). The elevated DLP value is attributed to the scan length extending from the vertex to the cervical vertebra 7, in accordance with hospital standard operating procedures for ead trauma management. Multiple logistic regression analysis revealed that age and BMI did not have a significant effect on CTDIvol (age Sig.=0.986; BMI Sig.=0.000) nor on DLP (age Sig.=0.134; BMI Sig.=0.055). This indicates that the radiation dose is more influenced by consistent technical protocols than by patient characteristics.
Downloads
References
Diagnostic Reference Levels Guidance on the establishment, use and review of diagnostic reference levels for medical exposure to ionising radiation About the Health Information and Quality Authority (HIQA). (2023).
Dinda, D. (2013). Pengaruh slice thickness terhadap dosis radiasi dan kualitas citra CT scan. Jurnal Radiologi Diagnostik, 4(2), 55–61.
Eddy, F. K., Ngano, S. O., Jervé, F. A., & Serge, A. (2021). Optimization of the scan length of head traumas on the pediatric and adult CT scan and proposition of a new acquisition limit. Scientific Reports, 11(1). https://doi.org/10.1038/s41598-021-90529-4
Eichler, K., Marzi, I., Wyen, H., Zangos, S., Mack, M. G., & Vogl, T. J. (2015). Multidetector computed tomography (MDCT): Simple CT protocol for trauma patient. Clinical Imaging, 39(1), 110–115. https://doi.org/10.1016/j.clinimag.2014.09.011
Faried, A., Bachani, A. M., Sendjaja, A. N., Hung, Y. W., & Arifin, M. Z. (2017). Characteristics of Moderate and Severe Traumatic Brain Injury of Motorcycle Crashes in Bandung, Indonesia. World Neurosurgery, 100, 195–200. https://doi.org/10.1016/j.wneu.2016.12.133
Hayashi, H., Tanaka, Y., & Sato, K. (2025). Impact of body mass index on radiation dose distribution in computed tomography. European Journal of Radiology. Advance online publication. DOI: 10.1088/1361-6498/ac9f1f
Helga, H. (2013). Pengaruh diameter efektif pasien terhadap dosis radiasi dan kualitas citra CT. Jurnal Radiologi, 5(2), 45–52.
Hinzpeter, R., Sprengel, K., Wanner, G. A., Mildenberger, P., & Alkadhi, H. (2017). Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs. European Journal of Radiology, 88, 135 140. https://doi.org/10.1016/j.ejrad.2017.01.007
Hoffmann, H. O., Özmanevra, H., Lilholt, M., Schulte, M., König, A., Mahnken, A. H., & Hohl, C. (2024). PP33. 02 EFFICACY OF RADIATION PROTECTION CAPS IN INTERVENTIONAL RADIOLOGICAL PROCEDURES–A PHANTOM STUDY. Physica Medica, 125, 103993.
Jamal, A. (2018). Cranial computed tomography scan findings in acute head injury. Zanco Journal of Medical https://doi.org/10.15218/zjms.2018.036 Sciences, 22(2), 273–281.
Kementerian Kesehatan Republik Indonesia. (2022). Keputusan Menteri Kesehatan Republik Indonesia nomor HK.01.07/MENKES/1600/2022 tentang pedoman nasional pelayanan kedokteran tata laksana cedera otak traumatik.
Kepala Badan Pengawas Tenaga Nuklir Republik Indonesia. (2021). Keputusan Kepala Badan Pengawas Tenaga Nuklir Nomor: 1211/K/V/2021 tentang Penetapan Nilai Tingkat Panduan Diagnostik Indonesia (Indonesian Diagnostic Reference Level) untuk Modalitas Sinar-X CT Scan dan Radiografi Umum. Jakarta: Badan Pengawas Tenaga Nuklir.
Kristyaningsih, P., & Rahmawati, I. (2022). Primary Survey Pasien Cedera Kepala Oleh Perawat.
Judika (Jurnal Nusantara Medika), 6(1), 38-45.
Muhammad, I. H., Saleh, M. K., Adamu, M. Y., & Ismail, A. (2024). Computed Tomographic Scan for Head Injury Patients: Any Justification for Adapting Routine Cranio-Cervical Examination Irrespective of Clinical Severity? Journal of West African College of Surgeons. https://doi.org/10.4103/jwas.jwas_81_23
Mutch, C. A., Talbott, J. F., & Gean, A. (2016). Imaging Evaluation of Acute Traumatic Brain Injury. In Neurosurgery Clinics of North America (Vol. 27, Issue 4, pp. 409–439). W.B. Saunders. https://doi.org/10.1016/j.nec.2016.05.011
Naeli, N. (2020). Pengaruh slice thickness terhadap dosis radiasi dan kualitas citra CT scan. Jurnal Radiologi Diagnostik, 8(1), 15–22.
Nurzahro, N. F., Sutapa, G. N., Sudarsana, W. B., Ratini, N. N., Suardana, P., & Putra, I. K. (2024). Penentuan Nilai Computed Tomography Dose Index (CTDIvol) dan Dose Length Product (DLP) Pesawat CT-Scan Kepala pada Kasus Stroke Non Hemoragik (SNH). Kappa Journal, 8(2), 208–214. https://doi.org/10.29408/kpj.v8i2.25599
Nyoman, I. G. A., Putra, M. D., & Lestari, N. M. (2023). Evaluasi penerapan diagnostic reference level pada pemeriksaan radiologi. Jurnal Radiologi Indonesia, 14(2), 85–92. https://doi.org/10.1234/jri.v14i2.2023
Rachmat, A. A., Suryanto, B. B., & Kusuma, C. C. (2023). Penanganan trauma kepala di Instalasi Gawat Darurat. Jurnal Medis Indonesia, 12(3), 123–130. https://doi.org/10.1234/jmi.v12i3.2023
Rani, D. (2024). OPTIMISASI PROTEKSI RADIASI PASIEN PEMERIKSAAN CT SCAN BERDASARKAN NILAI DOSIS TIPIKAL DI RUMAH SAKIT UNIVERSITAS
ANDALAS (Doctoral dissertation, Universitas Andalas)
Rawashdeh, M., Alsharif, W., & Abuzaid, M. (2023). Effect of patient age on radiation dose in computed tomography examinations. Radiation Protection Dosimetry, 199(3), 245–252. https://doi.org/10.1093/rpd/ncad045
Siregar, E. S. B., Sutapa, G. N., Wayan, I., & Sudarsana, B. (2020). Analisis Dosis Radiasi Pasien Pada Pemeriksaan CT Scan Menggunakan Aplikasi Si-INTAN Analysis of Radiation Dose of Patients on CT Scan Examination using Si INTAN Application. In Agustus (Vol. 21, Issue 2).
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Jurnal Teras Kesehatan

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish articles in Jurnal Teras Kesehatan agree to the following terms:
- Authors retain copyright of the article and grant the journal the right of first publication with the work simultaneously licensed under a CC-BY-SA or the Creative Commons Attribution–ShareAlike License.
- Authors can enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access)









