Inovasi Alat Fiksasi Pada Pemeriksaan Radiografi Femur Proyeksi Lateral Cross Table (Sistematik Literature Review)

Authors

  • Suwandi Politeknik Al Islam Bandung
  • Surdiyah Asriningrum Politeknik Al Islam Bandung

DOI:

https://doi.org/10.38215/s0jkym52

Keywords:

design innovation, femur radiography, fixation device, lateral cross-table

Abstract

The cross-table lateral projection in femur radiography plays a crucial role in diagnosing lower limb trauma, particularly in critically ill patients who cannot be optimally repositioned. The main challenge in this procedure is maintaining limb stability to achieve optimal image quality while avoiding repeat exposures. Various fixation device innovations have been developed to enhance patient comfort, examination efficiency, and image quality. This study is a systematic literature review conducted using the PRISMA 2020 guidelines, with literature searches performed in PubMed, SpringerLink, and Google Scholar. Keywords included fixation device, cross-table lateral femur radiography, and trauma imaging. Out of 250 identified articles, 35 met the inclusion criteria and were thematically analyzed based on innovation type, design, materials, and clinical effectiveness. Results indicate innovation trends such as portable designs, adjustable modular systems, and the use of lightweight materials like aluminum and velcro straps. Clinically, these devices effectively reduce examination time, improve positional stability, enhance image quality, and minimize operator radiation exposure. In conclusion, innovative fixation devices significantly contribute to optimizing cross-table lateral femur radiography, with recommendations for further prototype development and direct clinical trials.

Downloads

Download data is not yet available.

References

Addevico, F., Guardamagna, L., Roselli, M., De Paolis, M., Russo, A., & Maccauro, G. (2022).

Magnetic Resonance Imaging of the Knee in the Presence of Bridging External Fixation: A Comparison of Four MRI-Conditional Devices. Journal of Functional

Morphology and Kinesiology, 7(1), 4. https://doi.org/10.3390/jfmk7010004

Barrientos, Brañes, J., Wulf, R., Barahona, M., & Carvajal Fuentes, S. (2021). Scissor Position of

the Orthopedic Table for the Resolution of Intertrochanteric and Subtrochanteric Hip Fractures. Cureus, 13(7). https://doi.org/10.7759/CUREUS.16442

Baumgartner, L., Willburger, R. E., Strohm, P. C., & Suedkamp, N. P. (2016). Reduction of radiation

exposure from C-arm fluoroscopy during orthopaedic trauma operations with introduction of real-time dosimetry. Journal of Orthopaedic Trauma, 30(2), e53–e58. https://pubmed.ncbi.nlm.nih.gov/26360538/

Çepni, S., Özdemir, G., & Uğurlu, M. (2019). Comparison of intraoperative radiation exposure with and

without use of distal targeting device: A randomized control study. Journal of Orthopaedic Trauma, 33(7), 346–350. https://pubmed.ncbi.nlm.nih.gov/31278509/

Cho, H.-H., Lee, S.-M., & You, S.-K. (2019). Effect of using immobilization device in

fluoroscopic study in pediatric patient: Focused on radiation dose reduction in voiding cystourethrogram.

PLoS ONE, 14(10), e0224063. https://doi.org/10.1371/journal.pone.0224063

De Aguiar, T. O., Oliboni, L. S., Dezotti, V. M., Kennedy, N. I., Ferrari, M. B., & Gomes, J. L. E.

(2017). Simultaneous Radiographic Technique to Evaluate Ankle Instability. Arthroscopy Techniques, 6(6). https://doi.org/10.1016/J.EATS.2017.08.028

Evans, R., McCoy-Powlen, I., & Swartz, E. (2016). Effectiveness of cervical spine

immobilisation techniques: a comparative study using 3D motion analysis. European Spine Journal, 25(4), 1040–1047. https://doi.org/10.1007/s00586-016-4379-6

Ganjale, S. B. (2020). Long PFN nailing in comminuted high subtrochanteric fractures femur in lateral

position on ordinary table. Indian Journal of Orthopaedics Surgery, 4(3), 273–281. https://doi.org/10.18231/2395-1362.2018.0054

Haidar, L. A., Sliwinski, L., Warth, R. J., & Mansour, A. (2021). Placement of Provisional

External Fixation of Pediatric Femoral Shaft Fractures Using Radiopaque Markers in the Setting of Severe Polytrauma: A Technical Report. Techniques in Orthopaedics, 36(1), 82–86. https://doi.org/10.1097/BTO.0000000000000383

Lee, W. C., Luo, F. Y., Tiong, K. K. Q., Chia, N. W. K., Tham, L. M. H., & Tan, T. J. (2017). Accuracy of a modified axiolateral radiographic hip projection in suspected cases of hip fracture: experience and results from a regional trauma centre. Emergency Radiology, 24(1), 7–11. https://doi.org/10.1007/S10140-016-1434-X

Miao, K. H., & Miao, J. H. (2023). Radiological Diagnosis and Imaging of Femoral Shaft Fractures.

Anatomia. https://doi.org/10.3390/anatomia2030026

Nuanprom, P., Yuksen, C., Tienpratarn, W., & Jamkrajang, P. (2024). Traditional Spinal

Immobilization versus Spinal Motion Restriction in Cervical Spine Movement; a

Randomized Crossover Trial .Archives of Academic Emergency Medicine, 12(1), e36. https://doi.org/10.22037/aaem.v12i1.2263

Olsson, O., Karlsson, J., & Johnell, O. (2011). Can fluoroscopy radiation exposure be measured

in minimally invasive trauma surgery? The Journal of Bone and Joint Surgery. British Volume, 93(7), 1123–1127. https://pubmed.ncbi.nlm.nih.gov/21943776/

Surgery, 138(11), 1565–1573. https://doi.org/10.1007/s00402-018-3021-y

Patra, S. K., Shetty, A. P., Jayaramaraju, D., & Rajasekaran, S. (2019). Intraoperative

fluoroscopy-based radiation in orthopedic trauma: Correlation with surgery type and surgeon experience. Journal of Orthopaedics and Trauma, 33(2), e52–e57. https://doi.org/10.1097/BOT.0000000000001345

Patel, A. M., Yang, B. P., Smith, M. L., & Smith, D. L. (2021). CT in patients with external

fixation for complex lower extremity fractures: Impact of iterative metal artifact reduction techniques on metal artifact burden and subjective quality. AJR. American Journal of Roentgenology, 217(6), 1242–1248. https://doi.org/10.2214/AJR.21.26442

Peters, A. W., Harris, T. J., Rinehart, D., Sohn, G. H., Grewal, I. S., Starr, A., & Sanders, D.

(2023). Technical Trick: Traction Table Assisted Lateral Decubitus Patient Positioning in Cephalomedullary Nailing of Geriatric Intertrochanteric Femur Fractures. Journal of Orthopaedics and Trauma (Print). https://doi.org/10.1097/bot.0000000000002726

Pisoudeh, K., Elahifar, O., Alimoghadam, S., & Eslami, A. (2023). Trans-Table Intraoperative

Fluoroscopic Technique for Obtaining a True Lateral View of the Proximal Femur in the Lateral Decubitus Position. 11(8), 531–534. https://doi.org/10.22038/abjs.2023.73085.3386

Raposo, A. H., Ribeiro, R. Q., Côrtes Júnior, J. C. de S., & Aragão, I. P. B. de. (2024). Ittf –

temporary immobilizer with proximal femur traction: device description and potentialities. International Journal of Health Science, 4(81), 2–11. https://doi.org/10.22533/at.ed.1594812429084

Rashid, M. S., Aziz, S., Haydar, S., Fleming, S. S., & Datta, A. (2018). Intra-operative

fluoroscopic radiation exposure in orthopaedic trauma theatre. European Journal of Orthopaedic Surgery & Traumatology, 28(1), 9–14. https://pubmed.ncbi.nlm.nih.gov/28798994/

Roux, A., Bronsard, N., Blanchet, N., & de Peretti, F. (2017). Radiation exposure evaluation

during minimally invasive trauma surgery: A prospective study of 250 cases. Orthopaedics & Traumatology: Surgery & Research, 103(6), 662–667. https://doi.org/10.1016/j.otsr.2017.07.013

Stokkeland, P.J., Andersen, E., Bjørndal, M.M. et al. Maintaining immobilisation devices on

trauma patients during CT: a feasibility study. Scand J Trauma Resusc Emerg Med 25, 84 (2017). https://doi.org/10.1186/s13049-017-0428-3

Temmesfeld, M. J., Dolatowski, F. C., Dolatowski, F. C., Borthne, A., Borthne, A., Utvåg, S.

E., & Hoelsbrekken, S. E. (2019). Cross-Table Lateral Radiographs Accurately Predict Displacement in Valgus-Impacted Femoral Neck Fractures. 4(1). https://doi.org/10.2106/JBJS.OA.18.00037

Ugur, F. (2023). Individualized fluoroscopic lateral femoral neck view for fixation of hip

fractures in the lateral decubitus position. Journal of Health Sciences and Medicine.

https://doi.org/10.32322/jhsm.1348153

van Gerven, P., Rubinstein, S.M., Nederpelt, C. et al. The value of radiography in the follow-up of extremity fractures: a systematic review. Arch Orthop Trauma Surg 138, 1659–1669 (2018). https://doi.org/10.1007/s00402-018-3021-y

Vig, K. S., Adams, C. T., Young, J. R., Perloff, E., O’Connor, C. M., & Czajka, C. M. (2021).

Patient Positioning for Proximal Femur Fracture Fixation: a Review of Best Practices. Current Reviews in Musculoskeletal Medicine, 14(4), 272–281. https://doi.org/10.1007/S12178-021-09710-X

Xu, J., Su, B., Zhang, W., Sun, H., Li, D., Cai, Z., Chen, M., Qiu, M., & Ma, R. (2020). 3D

simulation of radiographic projections to test and reduce the effect of pelvic tilt on the accuracy of cross-table lateral radiography. BMC Musculoskeletal Disorders, 21(1), 1–7. https://doi.org/10.1186/S12891-020-03858-2

Yoo, J.-I., Jeong, H., Na, J. B., Song, S.-Y., Kim, J.-T., Cha, Y.-H., & Park, C. H. (2019).

Comparison of intraoperative radiation exposure with and without use of distal targeting device: a randomized control study. Archives of Orthopaedic and Trauma Surgery, 139(11), 1579–1586. https://doi.org/10.1007/S00402-019-03238-Z

Yurteri, A., Mercan, N., Kiliç, M. S., & Yildirim, A. (2023). Trokanterik femur kırıklarında

lateral dekübit pozisyonu ve traksiyon masasının intramedüller çivilemeye etkisinin karşılaştırılması. Cukurova Medical Journal. https://doi.org/10.17826/cumj.1352439

Young, M., Dempsey, M., De La Rocha, A., & Podeszwa, D. A. (2015). The cross-table lateral

radiograph results in a significantly increased effective radiation dose compared with the Dunn and single frog lateral radiographs. Journal of Pediatric Orthopaedics, 35(2), 157–161. https://doi.org/10.1097/BPO.0000000000000231

Zhang et al. (2020) – 3D simulation of pelvic tilt effect on cross table lateral radiography

Published

2026-01-16

How to Cite

Inovasi Alat Fiksasi Pada Pemeriksaan Radiografi Femur Proyeksi Lateral Cross Table (Sistematik Literature Review). (2026). Jurnal Teras Kesehatan, 9(1), 9-23. https://doi.org/10.38215/s0jkym52

Similar Articles

11-20 of 32

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)