Evaluasi Dosis Paparan Radiasi Pada Pemeriksaan MSCT Stonografi Kasus Urolithiasis Di Rumah Sakit Umum Pusat Dr. Hasan Sadikin Bandung.
DOI:
https://doi.org/10.38215/20zmyg78Keywords:
diagnostic reference levels (DRL), MSCT stonography, radiation dose, technical parameters, urolithiasisAbstract
Multislice Computed Tomography (MSCT) stenography is one of the preferred modalities for evaluating urolithiasis due to its high diagnostic accuracy. However, the increasing use of CT imaging has raised concerns regarding patient radiation exposure. This study aims to evaluate the radiation dose received by patients undergoing MSCT stenography at Dr. Hasan Sadikin General Hospital, Bandung, and to assess the influence of technical parameters on dose variability. This is a quantitative descriptive study using a cross-sectional approach. A total of 40 adult patients (male and female) who underwent MSCT stenography were selected as samples. Radiation dose data, including CTDIvol and DLP, were collected directly from the CT console and supported by patients’ medical records. Multiple linear regression analysis was performed to assess the relationship between CT dose and technical parameters such as kV, mAs, scan range, and volume of focus (VOF). The research showed that the average CTDIvol was 11.83 mGy and the average DLP was 644.64 mGy·cm, both of which exceeded the international Diagnostic Reference Levels (DRLs). Statistical analysis showed that only the mAs parameter had a significant effect on CTDIvol (p = 0.043), while other parameters such as kV, scan range, and VOF showed no significant influence.
Downloads
References
Alharbi, A. M. (2025). Optimizing CT Scan Protocols for Improved Image Quality and Reduced Radiation Dose. Journal of Advances and Scholarly Research in Allied Education, 52–56.
Andonian, S. (2022). Not Every Low-Dose Is Low-Dose: Impact of Revising Low-Dose CT Protocol on Mean Effective Radiation Exposure. Journal of Endourology.
Arfat, M., & Haq, A. B. (2024). Optimization of CT radiation dose: Insight into DLP and CTDI. Deleted Journal, 148–152.
Bilqis, A., Nurhanivah, D., & Ramdhani, S. Z. (2025). Comparison of CTDIw and Effective mAs as Predictors of Effective Dose in Thoracic CT Examinations: A Retrospective Analysis. International Journal of Health, Medicine and Sports, 112–116.
Deliie, S. T., Nebiyou, T., Tadesse, D. A., & Kabede, T. (2022). Computed Tomography Radiation Exposure among Urinary Tract Stone Patients at Tikur Anbessa Specialized Hospital: A Retrospective Study. Ethiop J Health Sci, 33-40.
Inoue, Y. T. (2022). Factors affecting dose-length product of computed tomography component in whole-body positron emission tomography/computed tomography. Journal of Radiological Protection.
Izzudin, M., Sukmaningtyas, H., & Sulaksono, N. (2021). Analysis of Window Widht Variation on Image Anatomical Information MSCT Stonography. Journal of Applied Health Management and Technology Vol 3, No 2 (2021) 40-45, 1-6.
Jaiswal, P., Shrestha, S., Dwa, Y., Maharjan, D., & Sherpa, N. (2022). CT KUB evaluation of suspected urolithiasis. Journal of Patan Academy of Health Sciences i, 58-64.
Larson, D. B. (2024). A Vision for Global CT Radiation Dose Optimization. Journal of The American College of Radiology., 1311 - 1317.
Prabsattroo, T. (2023). The Dose Optimization and Evaluation of Image Quality in the Adult Brain Protocols of Multi-Slice Computed Tomography: A Phantom Study. ournal of Imaging.
Rohi, B. P., Diartama, A. A., & Darmita, I. M. (2024). Pengaruh variasi rotation time terhadap ctdi (ct dose index) dan dlp (dose length product) pada pemeriksaan ct abdomen non kontras. Prepotif, 8(2), https://doi.org/10.31004/prepotif.v8i2.31910, 3841–3846.
Sari, A. W., & Sam, S. Y. (2021). Effect of mAs on the Radiation Doses Received by Eyes Organ at Cranium Examination. Proceedings of the 1st International Conference on Electronics, Biomedical Engineering, and Health Informatics. Lecture Notes in Electrical Engineering, vol 746 (pp. 541–547). Singapore: Springer.
Wang, Y., & Chu, P. W.-B. (2023). CT acquisition parameter selection in the real world: impacts on radiation dose and variation amongst 155 institutions. European Radiology, 1605–1613,.
Wulandari, P. I. (2023). A COMPREHENSIVE REVIEW OF INDONESIAN DIAGNOSTIC REFERENCE LEVELS (IDRLs) FOR CT SCAN EXAMINATIONS. Journal of Medical Imaging and Radiation Sciences,.
Yutaka , D., Keisuke, A., Onodera, S., Kayano, S., Hideki, O., & Takase, K. (2024). Introduction and evaluation of size-specific DLP for radiation dose estimation in CT examinations. Journal of Radiological Protection.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 Jurnal Teras Kesehatan

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Authors who publish articles in Jurnal Teras Kesehatan agree to the following terms:
- Authors retain copyright of the article and grant the journal the right of first publication with the work simultaneously licensed under a CC-BY-SA or the Creative Commons Attribution–ShareAlike License.
- Authors can enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access)









