EVALUASI HASIL RADIOGRAF CRANIUM PROYEKSI ANTERO POSTERIOR MENGGUNAKAN VARIASI KV DI INSTALASI RADIOLOGI RUMAH SAKIT HERMINA ARCAMANIK

THE EVALUATION OF CRANIUM RADIOGRAF USING ANTERO POSTERIOR PROJECTION WITH DIFFERENT kV AT RADIOLOGICAL DEPARTMENT OF HERMINA HOSPITAL IN ARCAMANIK

Authors

  • Farhan Nurrohman Politeknik Al Islam Bandung
  • Ardiana Politeknik Al Islam Bandung
  • Dian Nuramdiani Politeknik Al Islam Bandung

DOI:

https://doi.org/10.38215/jtkes.v7i2.142

Keywords:

: anatomical information, cranium radiograph, kV variation

Abstract

The provision of exposure factors is the key to producing quality radiographs in providing accurate anatomical information. This study aimed to determine the difference in anatomical information from radiographs of cranium examination as an indication of radiograph quality in the selection of several exposure factors. The study was conducted at Hermina Arcamanik Hospital in April 2024. A phantom cranium was used as the object, and the exposure factor was set at a variation of the tube voltage value 60-80kV with the tube current value fixed at 20mAs. The radiographs were evaluated for anatomical details and analyzed through the Friedman test. The results showed that the anatomical information for each tube voltage value was 4.18 for 60kV, 3.91 for 65kV, 3.50 for 70kV, 2.27 for 75kV, and 1.14 for 80kV. The value of 60kV/20mAs has the highest mean rank value indicating that this exposure factor provides the most optimal anatomical detail

Downloads

Download data is not yet available.

References

Bapeten. (2020). Peraturan Badan Pengawas Tenaga Nuklir No 4 Tahun 2020 Keselamatan Radiasi pada Penggunaan Sinar-X dalam Radiologi Diagnostik dan Intervensional. jakarta: BPTN.

Bontrager, K. L., & Lampignano, J. P. (2014). Handbook of Radiographic Positioning and Techniques. St Louis: Elsevier.

Fahmi, A., Firdausi, K. S., & Budi, W. S. (2008, Oktober). Pengaruh Faktor Eksposi Pada Pemerksaan Abdomen Terhadap Kualitas Citra Radiografi dan Paparan Radiasi Menggunakan Computed Radiography, Berskala Fisika. Berskala fisika, 11, 109-118.

Indrati, R., Susanto, E., Abimanyu, B., Wibowo, A. S., Murniati, E., Darmini, . . . Rasyid. (2017). Proteksi radiasi bidang radiodiagnostik dan intervensional. Magelang: Inti Medika Pustaka.

Kurnianto, K., Putra, I. M., & Susila, I. P. (2013). Perekayasaan Perangkat Radiografi Digital untuk Industri. Prosiding Pertemuan Ilmial Perekayasaan Perangkat Nuklir, 261-274.

Lampignano, J. P., & Kendrick, L. E. (2018). Radiographic Positioning and Related Anatomy. St. Louis: Elsevier.

Long, B. W., Rollins, J. H., & Smith, B. J. (2016). Merril's Atlas of Radiographic Positioning and Prosedures (13th ed.). St. Louis: Elsevier.

Pradana, A. (2011). Pengukuran Penggunaan kV Pada Pemeriksaan Thorak Anak Terhadap Kualitas Gambar Dan Dosis Radiasi. Jakarta: FMIPA Universitas Indonesia .

Rasad, S. (2015). Radiologi Diagnostik. jakarta: FK UI.

Sari, A. W., & Fransiska, E. (2017). Pengaruh Faktor Eksposi dengan Ketebalan Objek pada Pemeriksaan Foto Thorax Terhadap Gambaran Radiografi. gunabangsa, 17-21.

Spaeth, A. B. (2019). Diagram Tube Housing Ray. England: Bing.

Sugiyono. (2013). Metodelogi Penelitian Kuantitatif, Kualitatif, dan R&D. Bandung: Alfabeta.

Sugiyono. (2016). Metode Penelitian Kuantitatif, Kualitatif, dan R & D. Bandung: Alfabeta.

Sugiyono. (2018). Metode Penelitian Kuantitatif. Bandung: Alfabeta.

Suryaningmara, W. B., Sumadi, W. J., Saputra, H., & Ekawati, N. P. (2023). Karakteristik Klinik Patologi Tumor-Tumor Tulang Rawan di RSUP Sanglah Tahun 2016-2020. Medina Udayana, 22-25.

Utami, A. P., Saputro, S. D., & Felayani, F. (2018). Radiologi Dasar I. Magelang: Inti Medika Pustaka.

Frank, Eugene D, Long, Bruce W, Smith, Barbara J, (2016). Merril’s Atlas of Radiographic Positiong and Positioning and Procedures.

Ningtias, D.R, Suryono, S., & Susilo. (2016). Pengaruh Kualitas Citra Digital.

Published

2024-07-29

How to Cite

EVALUASI HASIL RADIOGRAF CRANIUM PROYEKSI ANTERO POSTERIOR MENGGUNAKAN VARIASI KV DI INSTALASI RADIOLOGI RUMAH SAKIT HERMINA ARCAMANIK: THE EVALUATION OF CRANIUM RADIOGRAF USING ANTERO POSTERIOR PROJECTION WITH DIFFERENT kV AT RADIOLOGICAL DEPARTMENT OF HERMINA HOSPITAL IN ARCAMANIK. (2024). Jurnal Teras Kesehatan, 7(2), 19-26. https://doi.org/10.38215/jtkes.v7i2.142

Similar Articles

1-10 of 19

You may also start an advanced similarity search for this article.